Error code ED and EE
These errors do not usually occur in the normal use. The conceivable causes are noise
around the installation site, fluctuation of the power supply voltage, and failures in the
software.
An unidentified error occurred.
Error code EF
Unstable power supply was detected.
Error code F0
Malfunction of the flash memory on the main PCB
---
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Print Unable EF
Turn the power off and then back on again.
Step
Cause
Remedy
1
Irregular power supply detected Replace the low voltage power supply PCB
ASSY. Reset the irregular power supply
detection counter following the procedure
described in
VOLTAGE POWER SUPPLY PCB ASSY" in
Chapter 4
2
Main PCB failure
Replace the main PCB ASSY.
CAUTION:
• The irregular power supply detection error (error code EF) occurs when there is a large
distortion in the power supply voltage supplied to the machine.
In this case, if the same power supply is used, the same error may occur even when
the low voltage power supply PCB ASSY is replaced. Ask the user to review the
installation environment.
Print Unable
Turn the power off and then back on again.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Malfunction of firmware
Rewrite the latest firmware.
2
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for FAX-2950
Page 20: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 35: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 45: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Page 122: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 130: ...3 6 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 136: ...3 12 Confidential 3 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Page 204: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 217: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 224: ...5 5 Confidential Black and white color scanning Fig 5 1 ...
Page 263: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 266: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 267: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Page 269: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 273: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...
Page 275: ...Confidential APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL FOR DRUM UNIT ...