V
- 15
WSW04
(TRANSFER facility setting)
Selector
No.
Function
Setting and Specifications
1
Earth function in transfer facility
0: Provided
1: Not provided
2
3
Dual tone detection frequency in
ICM recording
No. 2 3
0 0
:
350 and 440 Hz (A)
0 1
: 440 and 480 Hz (B)
1 x
: 480 and 620 Hz (C)
4
Tone detection sensitivity in ICM
recording
0: OFF
1: High
5
6
Earth time length for earth
function
No. 5 6
0 0
:
200 ms
0 1
:
300 ms
1 0
:
500 ms
1 1
:
700 ms
7
8
Break time length for flash
function
No. 7 8
0 0
:
80 ms
0 1
:
110 ms
1 0
:
250 ms
1 1
:
500 ms
NOTE:
Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is
supported.
NOTE:
Selectors 2 through 4 are applicable to those models equipped with a built-in TAD.
NOTE:
Selectors 2 and 3 are applicable in the U.S.A.
l
Selector 1:
Earth function in transfer facility
This selector determines whether or not the earth function is added to the transfer setting menu to
be accessed by the function switch.
l
Selectors 2 and 3: Dual tone detection frequency in ICM recording
If the equipment detects either of the frequencies set by these selectors in ICM recording, it will
disconnect the line. For example, if these selectors are set to “0, 0,” the equipment will disconnect
the line upon detection of 350 Hz or 440 Hz.
l
Selectors 4: Tone detection sensitivity in ICM recording
Setting this selector to “1” increases the tone detection sensitivity in ICM recording.
l
Selectors 5 and 6: Earth time length for earth function
These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground.
This setting is effective only when the earth function is selected for the R key by using the function
switch.
l
Selectors 7 and 8: Break time length for flash function
These selectors set the break time length.
This setting is effective only when the flash function is selected for the R key by using the function
switch.
Summary of Contents for FAX 750
Page 4: ...CHAPTER I GENERAL DESCRIPTION ...
Page 11: ...CHAPTER II INSTALLATION ...
Page 12: ...CHAPTER III THEORY OF OPERATION ...
Page 14: ...III 1 1 OVERVIEW Not provided on the FAX 910 ...
Page 24: ...III 11 Active Gears on the Inner Side of the Drive Unit ...
Page 26: ...III 13 Active Gears on the Inner Side of the Drive Unit ...
Page 30: ...III 17 Location of Sensors and Actuators 1 ...
Page 31: ...III 18 Not provided on the FAX 910 Location of Sensors and Actuators 2 ...
Page 34: ...III 21 FAX750 FAX770 FAX 910 FAX 920 FAX 921 MFC 925 FAX870MC FAX 930 FAX 931 MFC970MC ...
Page 39: ...CHAPTER IV DISASSEMBLY REASSEMBLY LUBRICATION AND ADJUSTMENT ...
Page 44: ...IV 4 n n Disassembly Order Flow ...
Page 48: ...IV 8 4 Disconnect the panel main harness ...
Page 52: ...IV 12 ...
Page 70: ...IV 30 Remove the two screws and lift up the paper feed chute ...
Page 72: ...IV 32 ...
Page 78: ...IV 38 ...
Page 86: ...IV 46 1 17 Harness Routing ...
Page 88: ...IV 48 ...
Page 89: ...IV 49 2 LF roller ASSY 3 Platen frame ASSY ...
Page 90: ...IV 50 ...
Page 91: ...IV 51 4 Separation roller and main frame ...
Page 92: ...CHAPTER V MAINTENANCE MODE ...
Page 99: ...V 6 Scanning Compensation Data List ...
Page 150: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Page 168: ...July 98 5X4401 Printed in Japan ...
Page 177: ......
Page 178: ......
Page 182: ......
Page 184: ......
Page 197: ......
Page 198: ......
Page 202: ......
Page 216: ......
Page 218: ......