HE-800B
3. INSTALLATION
18
<100 V / 400 V system>
(1) Power switch
(2) Screws [2 pcs]
(3) Transformer box
(4) Transformer box plates [2 pcs]
(5) Screw [with washer]
(6) 3-pin power supply connector
(7) Staples [6 pcs]
(8) Cord clamps [2 pcs]
(9) Power cord
1. Attach an appropriate plug to the
power cord (9). (The green and
yellow wire is the ground wire.)
2.
Insert the power plug into a
properly-grounded AC power supply.
* The inside of the control box uses
single-phase power.
NOTE:
• If the ground connection is not
secure, electric shocks, operating
errors or damage to electronic
components such as P.C. boards
may occur.
• Take care when tapping in the
staples (7) to make sure that they do
not pierce the cords.
•
Do not use extension cords,
otherwise machine operation
problems may result.
3. Use the six screws to tighten the
cover of the control box. Check that
none of the cords are being clamped
by the cover at this time.
Green and yellow wire
(ground wire)
4145M
4758M
4936M
Operator