10. TABLE OF ERROR CODES
HE-800B
142
10. TABLE OF ERROR CODES
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before
opening the control box cover. Touching areas where high voltages are present will result in serious injury from
electric shocks.
If a problem should occur with the sewing machine, the buzzer will sound and an error code and error message will appear in
the display.
Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
Cause
Remedy
E010
Stop switch was pressed during standby. Remove your finger from the stop switch (so that it is off).
E011
Stop switch was pressed during sewing.
Press the RESET key to clear the error.
* Press the key to move the needle and the work
clamp so that you can continue sewing.
* If not continuing sewing, press the RESET key once
more.
E012
Stop switch was pressed while sewing
machine was operating other than during
sewing.
Press the RESET key to clear the error.
(Home position detection will be carried out automatically.)
E015
The stop switch was still pressed when
the power was turned on, or there is a
problem with the stop switch connection.
Turn off the power and check the connection of the stop
switch connector P9 at the main P.C. board.
E016
Problem with the stop switch connection. Turn off the power and check the connection of the stop
switch connector P9 at the main P.C. board.
E025
Treadle was still depressed to the 2nd
step when the power was turned on, or
treadle connection is faulty.
(Start switch if a triple pedal is being used)
Turn off the power, and then check that connector P12 on
the motor P.C. board is properly connected. (Connector
P15 on the main P.C. board if a triple pedal is being used)
E035
Treadle was still depressed to the 1st step
when the power was turned on, or treadle
connection is faulty.
(Work clamp switch if a triple pedal is
being used)
Turn off the power, and then check that connector P12 on
the motor P.C. board is properly connected. (Connector
P15 on the main P.C. board if a triple pedal is being used)
E045
Treadle was still depressed backward
when the power was turned on, or treadle
connection is faulty.
(Work clamp lifter switch if a triple pedal is
being used)
Turn off the power, and then check that connector P12 on
the motor P.C. board is properly connected. (Connector
P15 on the main P.C. board if a triple pedal is being used)
4933M
Flashing
Summary of Contents for HE-800B
Page 7: ...v HE 800B Oil tank accessory 4732M 4731M 4730M ...
Page 75: ...6 ASSEMBLY HE 800B 66 D E 0688D 0690D ...
Page 126: ...9 ELECTRIC MECHANISM HE 800B 117 Power PCB Cutter PCB LCD panel PCB 0831D 0768D 0769D ...
Page 133: ...9 ELECTRIC MECHANISM HE 800B 124 0851D ...
Page 134: ...9 ELECTRIC MECHANISM HE 800B 125 0852D ...
Page 135: ...9 ELECTRIC MECHANISM HE 800B 126 0853D ...
Page 177: ...MEMO 168 HE 800B ...
Page 178: ...SERVICE MANUAL 2014 Brother Industries Ltd All Rights Reserved HE 800B I3061003D 2014 03 D 1 ...