3. FUNCTION SETTINGS
8
3-4. List of memory switches
NOTE:
In standard memory switch setting mode (refer to the CD instruction manual), the bottom two digits only display memory
switch Nos. 00 to 49.
To make the bottom two digits display memory switch Nos. 50 to 99, switch the sewing machine to Administrator memory
switch setting mode. (Refer to the previous page.)
Work clamp setting (001 to 099)
No.
Setting items
Setting range Default value
001
Work clamp height when treadle is depressed.
Settings can be made in units of 1 mm.
1 to 13
13
002
Work clamp height when treadle is at neutral position.
Settings can be made in units of 1 mm.
1 to 13
10
003
Work clamp operation when treadle is depressed to the 1st step.
* When using a triple pedal (optional part), this number will not be
displayed.
1: Work clamp does not drop to intermediate position.
2: Work clamp drops to intermediate position.
1 to 2
1
004
Work clamp height (mm) when dropped to intermediate position.
* Displayed when No. 003 above is set to “2”.
Settings can be made in units of 0.1 mm.
0.1 to 8.0
1.0
050
*1
Sewing machine starting procedure (pedal type).
1: Treadle.
3: Triple pedal.
1,3
1
052
Pausing enabled during automatic sewing when treadle is depressed backward.
* When using a triple pedal (optional part), this number will not be
displayed.
OFF: Pausing is not allowed.
ON: Pausing is allowed.
ON/OFF
OFF
053
Work clamp operation when using a triple pedal.
* When using a treadle, this number will not be displayed. (Refer to P. 15.)
* Neutral indicates that the work clamp is at the neutral position.
1: Remains lowered even when the work clamp switch is released, intermediate
lowering disabled, and starting prohibited when at neutral.
2: Remains lowered even when the work clamp switch is released, intermediate
lowering enabled, and starting prohibited when at neutral.
3: Remains lowered even when the work clamp switch is released, intermediate
lowering disabled, and starting allowed when at neutral.
4: Remains lowered even when the work clamp switch is released, intermediate
lowering enabled, and starting allowed when at neutral.
5: Returns to neutral when the work clamp switch is released, intermediate
lowering disabled, and starting prohibited when at neutral.
6: Returns to neutral when the work clamp switch is released, intermediate
lowering enabled, and starting prohibited when at neutral.
7: Returns to neutral when the work clamp switch is released, intermediate
lowering disabled, and starting allowed when at neutral.
8: Returns to neutral when the work clamp switch is released, intermediate
lowering enabled, and starting allowed when at neutral.
1 to 8
1
*1 This is not initialized during initialization mode. Also not overwritten from SD card.
Summary of Contents for HE-800B
Page 7: ...v HE 800B Oil tank accessory 4732M 4731M 4730M ...
Page 75: ...6 ASSEMBLY HE 800B 66 D E 0688D 0690D ...
Page 126: ...9 ELECTRIC MECHANISM HE 800B 117 Power PCB Cutter PCB LCD panel PCB 0831D 0768D 0769D ...
Page 133: ...9 ELECTRIC MECHANISM HE 800B 124 0851D ...
Page 134: ...9 ELECTRIC MECHANISM HE 800B 125 0852D ...
Page 135: ...9 ELECTRIC MECHANISM HE 800B 126 0853D ...
Page 177: ...MEMO 168 HE 800B ...
Page 178: ...SERVICE MANUAL 2014 Brother Industries Ltd All Rights Reserved HE 800B I3061003D 2014 03 D 1 ...