2-71
Confidential
■
Error code C4
Paper tray 2 pressing plate up/down error.
<User Check>
- Check if the paper tray 2 is installed into the printer.
■
Error code C5
Energization failure of erase lamp
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
Tray 2 Error
Take out Tray 2 and push it back in firmly.
Step
Cause
Remedy
1
Harness connection failure of
T2 plate motor ASSY
Check the harness connection of the
T2 plate motor ASSY and reconnect it.
2
Harness connection failure of
T2 Relay PCB ASSY
Check the harness connection of the
T2 Relay PCB ASSY and reconnect it.
3
T2 plate-up detection sensor
failure
Check the sensor performance following
the procedure described in
. If any problem occurs, replace the T2
paper feed frame unit.
4
T2 Relay PCB ASSY failure
Replace the T2 Relay PCB ASSY.
5
Engine PCB failure
Replace the engine PCB ASSY.
6
T2 plate motor ASSY failure
Replace the paper tray 2.
-
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for HL-4140CN
Page 19: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 29: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 145: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 169: ...3 21 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 296: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 311: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 336: ...5 23 Confidential Inter color position alignment adjustment chart Fig 5 8 ...
Page 343: ...5 30 Confidential Fig 5 11 ...
Page 345: ...5 32 Confidential Fig 5 12 First side Second side ...
Page 347: ...5 34 Confidential Color test pattern Fig 5 13 MCYK Y C K M YCMK_ _A ...
Page 354: ...5 41 Confidential Maintenance information Fig 5 14 ...
Page 382: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 384: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 385: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 386: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 387: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 388: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 389: ...6 6 Confidential 2 WIRING DIAGRAM Wiring Diagram ...
Page 390: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 424: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 428: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 432: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...