1.4 Detailed Description of Maintenance-mode Functions
1.4.1 EEPROM parameter initialization (Function code 01, 91)
<Function>
This function initializes the setting values of the operation parameters, user switches, and
worker switches (WSW) registered in the EEPROM.
Entering function code 01 initializes almost all of the EEPROM areas, but entering 91 does not
initialize some areas, as listed below.
<Operating procedure>
(1) Press the
or
button to display “MAINTENANCE 01” (or “MAINTENANCE 91”
according to your need) on the LCD in the initial state of the maintenance mode.
Then, press the
OK
button. The “PARAMETER INIT” appears on the LCD.
(2) Upon completion of parameter initialization, the printer returns to the initial state of the
maintenance mode.
Data item
Function code 01
Function code 91
Printer switch
- Counter information
These will
not
be
initialized.
These will
not
be
initialized.
Error history
MAC address (Ethernet Address)
Operation lock of the control panel
password
These will be
initialized.
Secure function lock
Worker switch
User switches (Items to be initialized
when resetting to the factory default
settings)
These will be
initialized.
Function settings except user switches
(Items except the factory default settings)
- Languages
- Reprint
- Secure print
- Interfaces
LAN area (Network settings)
PCL core area
(Emulation settings)
Note:
Function code 01 is for service personnel. Function code 91 is for user support.
Summary of Contents for HL-4140CN
Page 19: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 29: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 145: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 169: ...3 21 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 296: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 311: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 336: ...5 23 Confidential Inter color position alignment adjustment chart Fig 5 8 ...
Page 343: ...5 30 Confidential Fig 5 11 ...
Page 345: ...5 32 Confidential Fig 5 12 First side Second side ...
Page 347: ...5 34 Confidential Color test pattern Fig 5 13 MCYK Y C K M YCMK_ _A ...
Page 354: ...5 41 Confidential Maintenance information Fig 5 14 ...
Page 382: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 384: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 385: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 386: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 387: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 388: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 389: ...6 6 Confidential 2 WIRING DIAGRAM Wiring Diagram ...
Page 390: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 424: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 428: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 432: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...