5-35
Confidential
1.4.18 Sensitivity adjustment of density sensor (Function code 72)
<Function>
This function allows you to print the patch data for density sensor sensitivity adjustment on the
belt unit and measure the density with the density sensor. The characteristics of the density
sensor are calculated based on the value measured by the density sensor, and the parameter
is adjusted upon color density adjustment.
<Operating procedure>
(1) Press the
or
button to display “MAINTENANCE 72” on the LCD in the initial state of
the maintenance mode. Then, press the
OK
button. “PLEASE WAIT” is displayed on the
LCD.
(2) When the parameter is obtained without errors, the printer returns to the initial state of the
maintenance mode.
When an error message is displayed on the LCD, take the measures described in the
table below.
* # indicates the toner color (Y, M, or C) of which cartridge became empty.
Note:
If you replace the main PCB ASSY, be sure to carry out this procedure. This function
must not be executed until it is verified that the printer is in the ready state.
Error message
Measure
FAILED
Remove the error factors with the following operations and
press the
Go
button to clear the error.
- Re-insert the toner cartridge in the correct position.
- Replace the toner cartridge.
- Replace the drum unit.
- Replace the waste toner box.
- Replace the belt unit.
- Replace the registration mark sensor holder ASSY.
TONER EMPTY # *
Replace the empty toner cartridge and press the
Go
button
to clear the error. Perform the sensitivity adjustment of the
density sensor again.
Cover is Open
Close the front cover.
Replace Toner
Replace the black toner cartridge and press the
Go
button to
clear the error. Perform the sensitivity adjustment of the
density sensor again.
Summary of Contents for HL-4140CN
Page 19: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 29: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 145: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 169: ...3 21 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 296: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 311: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 336: ...5 23 Confidential Inter color position alignment adjustment chart Fig 5 8 ...
Page 343: ...5 30 Confidential Fig 5 11 ...
Page 345: ...5 32 Confidential Fig 5 12 First side Second side ...
Page 347: ...5 34 Confidential Color test pattern Fig 5 13 MCYK Y C K M YCMK_ _A ...
Page 354: ...5 41 Confidential Maintenance information Fig 5 14 ...
Page 382: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 384: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 385: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 386: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 387: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 388: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 389: ...6 6 Confidential 2 WIRING DIAGRAM Wiring Diagram ...
Page 390: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 424: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 428: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 432: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...