1-8
Confidential
2.5
Service Information
These are key service information to maintain the product.
Machine life: 200,000 pages
MTBF (Meantime between failure): Up to 4000 hours
MTTR (Meantime to repair): Average 0.5 hours
Monthly volume: 30,000 pages
Periodical replacement parts:
* As for periodical replacement parts, refer to
in the Service Manual.
Parts
Approximate Life (pages)
Fuser unit
100,000
Laser unit
100,000
PF kit
China
MP: 25,000
Tray 1/2/3: 100,000
India
MP: 12,000
Tray 1/2/3: 80,000
Others
MP: 50,000
Tray 1/2/3: 100,000