2-77
Confidential
■
Error code E000
Some ROM checksum error occurred.
Error code E100
Program error.
< User Check >
- Install the latest firmware.
■
Error code E500
Error occurred when DRAM on the main PCB ASSY was accessed.
Error code E600
Error occurred during writing to EEPROM on the main PCB ASSY.
Error code E702
Error occurred during reading from the flash ROM on the main PCB.
■
Error code EC00
Overcurrent was caused because a USB device that did not meet the specifications was
inserted into the USB port.
< User Check >
- Remove the USB device from the USB port and turn the power OFF. Turn it ON again after a
while.
- Replace the USB device with another one.
Print Unable E0
Turn off and on.
Print Unable E1
Turn off and on.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Print Unable E5
Turn the power off and then back on again.
Print Unable E6
Turn the power off and then back on again.
Machine Error E7
Turn off and on.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Unusable Device
Remove the Device. Turn the power off and back on again.
Step
Cause
Remedy
1
USB host relay PCB failure
Replace the USB host relay PCB ASSY.
2
Main PCB failure
Replace the main PCB ASSY.