5-14
Confidential
■
Location of sensors
Fig. 5-6
LCD
Sensor names
Detection status (displayed/not displayed)
MAC XXC
Internal temperature sensor
XX
°
C/NG
BT XXC
Belt temperature sensor
0
°
C (The value will not be changed since this
sensor is not installed.)
TMP XXC
External temperature sensor
XX
°
C/NG
HUM XXC
External humidity sensor
XX %/NG
Note:
If the external temperature/humidity sensor detects the unusual value, the machine displays
“NG” on the LCD.
(3) Check that the display on the LCD is
changed when the detection condition
of each sensor is changed.
For example, insert paper through the
registration front/rear sensor, open the
front cover or the back cover, remove
the toner cartridge, make a jam at the
paper outlet, insert paper from the MP
tray, set the paper tray, etc.
(4) Press the
Cancel
key and finish this
operation to return the machine to the
initial state of the maintenance mode.
(3) Check that the display on the LCD is
changed when the detection condition
of each sensor is changed.
For example, insert paper through the
registration front/rear sensor, open the
front cover or the back cover, remove
the toner cartridge, make a jam at the
paper outlet, insert paper from the MP
tray, set the paper tray, etc.
(4) Press the
X
key and finish this
operation to return the machine to the
initial state of the maintenance mode.
Registration front sensor
Registration rear sensor
External temperature sensor
T1 paper feed sensor
Front cover sensor
External humidity sensor
High-voltage power supply
Paper feed unit
Process drive unit
Registration front/rear
sensor PCB ASSY
PCB ASSY