5-24
Confidential
■
Switching of timing to execute Auto Registration
<Function>
Relative displacement between Cyan, Magenta, Yellow, and Black is detected using the
registration mark sensor, and the Auto Registration is executed at the timing when the
displacement value exceeds the stipulated threshold value.
This function is to switch the threshold value which is used as the timing to execute Auto
Registration. The threshold value can be switched in three phases between High, Mid, and
Low.
“*” is displayed at the end of the currently specified function in the LCD display.
<Operating procedure>
LCD
Description
Reg Freq=Mid
The frequency to execute Auto Registration is middle. (default)
Reg Freq=High
The frequency to execute Auto Registration is high.
Reg Freq=Low
The frequency to execute Auto Registration is low.
Note:
It can be set regardless of the Auto Registration switching function in the function menu.
Even if this function is switched, it does not affect the timing to execute Auto Registration in
the function menu.
Model without touch panel
Model with touch panel
(1) Press the
or
key to display
“MAINTENANCE 45” on the LCD in the
initial state of the maintenance mode.
Then, press the
OK
key. “USBNo.” is
displayed on the LCD.
(2) Press the
or
key to display
“RegiFreq” and then press the
OK
or
Go
key.
(3) Press the
or
key to select
“RegiFreq=Mid”, “RegiFreq=High” or
“RegiFreq=Low”, and press the
OK
or
Go
key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial
state of the maintenance mode.
(1) Press the
4
and
5
keys in this order in
the initial state of the maintenance
mode. “USBNo.” is displayed on the
LCD.
(2) Press the
or
key to display
“RegiFreq” and then press the
Mono
or
SET
key.
(3) Press the
or
key to select
“RegiFreq=Mid”, “RegiFreq=High” or
“RegiFreq=Low”, and press the
Mono
or
SET
key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial
state of the maintenance mode.