2-11
Confidential
050C
When the temperature of the
center thermistor of the fuser
unit is higher than the idle
temperature, the side thermistor
of the fuser unit detected a
temperature lower than the
specified value.
050D
---
050F
---
0600
---
0700
---
0800
Error occurred in the internal
temperature sensor.
0900
Machine detected more than
100 times that supplied power
was unstable.
0A01
The blower failure was detected.
0A02
The fuser fan failure was
detected.
0B01
Error occurred in the
high-voltage power supply PCB
ASSY while the machine is in
operation.
0B02
Error occurred in the
high-voltage power supply PCB
ASSY in the ready state.
0C00
Error occurred in the density
sensor.
0D01
---
0D02
---
0D03
---
0D04
---
0E00
Communication error occurred
in the high-voltage power supply
PCB ASSY.
1003
The registration mark sensor R
is dirty and cannot normally
receive reflected light.
Error
Codes
Description
Refer
to:
1004
The registration mark sensor L
is dirty and cannot normally
receive reflected light.
1100
---
1200
---
1300
---
1400
Condensation occurred in the
machine.
1500
Error occurred in the paper eject
origin sensor.
1C00
The reading signal of the
EEPROM of the laser unit
cannot be detected.
1D01
---
1D02
---
1D03
---
1D04
---
1E01
---
1E02
---
2001
---
2002
---
2003
---
2004
---
2005
---
2006
---
2101
---
2102
---
2103
---
2104
---
2105
---
2201
---
2202
---
2203
---
2204
---
2205
---
2206
---
2207
---
Error
Codes
Description
Refer