2-15
Confidential
6300
The waste toner sensor
detected that no waste toner box
was set.
6400
The registration mark sensor
detected that no belt unit was
set.
6602
---
6701
---
6801
The internal temperature sensor
or side thermistor of the fuser
unit detected a temperature
higher than the specified value.
6802
---
6901
Some fuser unit errors occurred
at power-ON or upon recovery
from sleep mode.
6902
After the errors was detected at
the fuser unit, power was turned
ON again and the error is being
checked. (If power is turned
OFF and ON after error code
6901 occurred, this code is
displayed for about 15 minutes.)
6A00
Electric discharge that may be
caused by dirt on the corona
wire of the drum unit was
detected.
6B01
Electric discharge was detected
when the number of the drum
unit rotations had become more
than twice of the upper limit.
6B02
---
6B03
---
6B04
---
6B0A
---
6C01
---
6C02
After the T2 paper tray unit is
opened and closed or the power
is turned ON, the T2 plate origin
sensor detects that lift-up of the
plate of the T2 paper tray unit is
not completed within the
specified period of time.
6C03
---
Error
Codes
Description
Refer
to:
6C04
---
6D00
---
6E00
The develop release sensor
detected the developer roller
disengagement or engagement
failure.
6F00
Machine detected that supplied
power was unstable.
(Less than 100 times)
7000
After the registration rear sensor
detects paper pass, the eject
sensor does not detect paper
pass.
7001
---
7002
---
7003
---
7004
---
7100
After the registration rear sensor
detects the end of paper pass
and the specified period of time
has passed, the eject sensor
continues to detect paper pass.
7101
---
7102
---
7103
---
7104
---
7105
---
7106
---
7200
When the paper is fed from the
MP tray, after the MP
registration front sensor detects
paper pass, the registration rear
sensor does not detect paper
pass after a set period of time.
7300
In the case of printing by feeding
paper from the paper tray 1,
after the T1 paper feed sensor
detects paper pass, the
registration front sensor does
not detect paper pass after a set
period of time.
7301
---
Error
Codes
Description
Refer