2-43
Confidential
■
Error code 0800
Error occurred in the internal temperature sensor.
■
Error code 0900
Machine detected more than 100 times that supplied power was unstable.
< User Check >
- Turn OFF the power switch. After several seconds, turn ON the power again and check that
this error is reset.
■
Error code 0A01
The blower failure was detected.
Print Unable 08
Turn the power off and then back on again.
Step
Cause
Remedy
1
Connection failure of the internal
temperature sensor harness
Reconnect the internal temperature
sensor harness.
2
Main PCB failure
Replace the main PCB ASSY.
Print Unable 09
Turn the power off and then back on again.
Step
Cause
Remedy
1
Low-voltage power supply PCB
failure
Replace the low-voltage power supply
PCB unit. After replacing the low-voltage
power supply PCB unit, refer to
Reset counters for parts (Function code
, and reset the irregular
power supply detection counter of the
low-voltage power supply PCB unit.
2
Main PCB failure
Replace the main PCB ASSY.
Note:
The irregular power supply detection error (Error code 0900) of the low-voltage power
supply PCB unit occurs when there is a large distortion in the power supply voltage supplied
to the machine. In this case, if the same power supply is used, the same error might occur
again even if the low-voltage power supply PCB unit is replaced.
For this reason, be sure to ask the user to rearrange the installation environment.
Print Unable 0A
Turn the power off and then back on again.
Step
Cause
Remedy
1
Connection failure of the blower
harness
Reconnect the blower harness.
2
Connection failure of the
high-voltage power supply PCB
harness
Reconnect the high-voltage power supply
PCB harness.
3
Blower failure
Replace the blower.
4
Low-voltage power supply PCB
failure
Replace the low-voltage power supply
PCB unit.
5
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
6
Main PCB failure
Replace the main PCB ASSY.