2-53
Confidential
■
Error code 6001
The front cover sensor detected that the front cover was open.
< User Check >
- Close the front cover.
■
Error code 6004
The eject sensor detected that the fuser cover was open.
< User Check >
- Close the fuser cover.
Cover is Open
Close the Front Cover.
Step
Cause
Remedy
1
Connection failure of the front
cover sensor harness
Reconnect the front cover sensor
harness.
2
Front cover failure
Replace the front cover.
3
Front cover sensor failure
Replace the front cover sensor.
4
Main PCB failure
Replace the main PCB ASSY.
Cover is Open
Close the Fuser Cover which can be found behind the Back Cover of the
machine.
Step
Cause
Remedy
1
Eject actuator that has come off
or that has been caught
Re-assemble the eject actuator.
2
Fuser cover installation failure
Re-assemble the fuser cover.
3
Connection failure of the eject
sensor PCB harness
Reconnect the eject sensor PCB harness.
4
Eject sensor PCB failure
Replace the eject sensor PCB ASSY.
5
Main PCB failure
Replace the main PCB ASSY.