2-42
Confidential
■
Error code 050A
The center thermistor or side thermistor of the fuser unit detected some temperature error in
the hardware.
Error code 050B
When the temperature of the center thermistor of the fuser unit is lower than the idle
temperature, the side thermistor of the fuser unit detected a temperature higher than the
specified value.
Error code 050C
When the temperature of the center thermistor of the fuser unit is higher than the idle
temperature, the side thermistor of the fuser unit detected a temperature lower than the
specified value.
< User Check >
- Turn OFF the power switch. After several seconds, turn ON the power again and check that
this error is reset.
Print Unable 05
Turn the power off and then back on again.
Print Unable 05
Turn the power off and then back on again.
Print Unable 05
Turn the power off and then back on again.
Step
Cause
Remedy
1
Connection failure of the center
or side thermistor harness of the
fuser unit
Reconnect the harness of the center
thermistor or side thermistor of the fuser
unit.
2
Connection failure of the heater
harness of the fuser unit
Reconnect the heater harness of the fuser
unit.
3
Connection failure of the eject
sensor PCB harness
Reconnect the eject sensor PCB harness.
4
Connection failure of the
low-voltage power supply PCB
harness
Reconnect the low-voltage power supply
PCB harness.
5
Eject sensor PCB failure
Replace the eject sensor PCB ASSY.
6
Fuser unit failure
Replace the fuser unit.
7
Low-voltage power supply PCB
failure
Replace the low-voltage power supply
PCB unit.
8
Main PCB failure
Replace the main PCB ASSY.