for Electronic Parts
Power does not come on
When the power is turned on,
nothing appears on the LCD.
Replace the main PCB assy.
Y
Connect the power supply
cord correctly or replace it.
Replace the inlet assy.
N
Is the power supply cord free from
damage and connected correctly?
Y
N
Y
Y
N
Replace the power supply
PCB assy.
Replace the power lead wire assy.
N
Is the resistance between the pins
1 & 1, 2 & 2, 3 & 3, 4 & 4 and 5 & 5
at the power lead wire assy. 1
Ω
or
less?
When the inlet assy. connector is
disconnected from the power supply
PCB assy. and the power is turned
on, is the voltage between pins
100V AC?
When the power lead wire assy. is
disconnected from the power supply
PCB assy. connector (CN202), are
the voltages between pins 2 & 3 and
4 & 3 normal?
• Between pins 2 & 3 : 5V DC
• Between pins 4 & 3 : 30V DC
Summary of Contents for HS-3000
Page 1: ......
Page 2: ......
Page 3: ......
Page 9: ...vi ...
Page 16: ...2 1 2 Disassembly Main parts 2 2 Feed unit 2 22 Needle presser unit 2 30 ...
Page 17: ...2 2 Main parts Main parts location diagram Main unit ...
Page 37: ...2 22 Feed unit location diagram Main unit ...
Page 45: ...2 30 Needle presser unit location diagram Main unit ...
Page 55: ...3 2 Main parts Main parts location diagram Main unit ...
Page 77: ...3 24 Main unit Main parts 36 Accessory table attachment 1 Attach the accessory table 1 1 ...
Page 78: ...3 25 Assembly Feed unit Feed unit location diagram Main unit ...
Page 90: ...3 37 Assembly Needle presser unit Needle presser unit location diagram Main unit ...
Page 163: ...7 12 ...
Page 164: ......