2 - 14
Main parts
Main unit
20
Power PCB assy. removal
1. Remove the ZPM lead wire assy.
1
from the guide parts
2
of the
insulation cover.
2. Remove screws
1
and
2
(1pc. /2 pcs.), and then remove the power PCB
assy.
3
.
3. Disconnect the main motor lead wire
4
and the inlet assy. connector
5
.
*Key point
• Hold the hook on the inlet assy. connector
5
and pull it out.
5
2
1
4
3
2
1
20-1
Power PCB assy. disassembly
1. Disconnect the power lead wire assy. connector
1
from the power PCB
assy.
2
.
2. Remove the screw
1
, and then remove the power plate spring
3
from the
power PCB assy.
2
.
3. Remove the screw
2
, and then remove the insulator sheet
4
and the
power PCB assy.
2
from the insulation cover.
1
3
1
2
4
2
21
Inlet assy. removal
1. Remove the screw
1
, and then remove the inlet assy.
1
from the rear
cover assy..
1
1
Summary of Contents for HS-3000
Page 1: ......
Page 2: ......
Page 3: ......
Page 9: ...vi ...
Page 16: ...2 1 2 Disassembly Main parts 2 2 Feed unit 2 22 Needle presser unit 2 30 ...
Page 17: ...2 2 Main parts Main parts location diagram Main unit ...
Page 37: ...2 22 Feed unit location diagram Main unit ...
Page 45: ...2 30 Needle presser unit location diagram Main unit ...
Page 55: ...3 2 Main parts Main parts location diagram Main unit ...
Page 77: ...3 24 Main unit Main parts 36 Accessory table attachment 1 Attach the accessory table 1 1 ...
Page 78: ...3 25 Assembly Feed unit Feed unit location diagram Main unit ...
Page 90: ...3 37 Assembly Needle presser unit Needle presser unit location diagram Main unit ...
Page 163: ...7 12 ...
Page 164: ......