Failure Investigation
for Electronic Parts
Problems with vertical needle movement and reverse stitching
Problems with vertical needle movement
and reverse stitching.
Reassemble the BW switch assy.
Replace the SSVR PCB assy.
Is the BW switch OFF?
Is the resistance for the start / stop
switch, reverse stitch switch and
needle position button normal?
• Switch resistance values
Switch depressed : 1
Ω
or less
Switch out : more than 1M
Ω
N
N
Y
Y
Replace the main PCB assy.