4 - 2
Test Mode
Starting test mode
•
With the front cover in place
Press
and
while turning the power on; the buzzer will sound four times, and test mode will start.
•
Without the front cover in place
Press SW1 and SW3 on the main PCB assy. while turning the power on; the buzzer will sound four times, and
test mode will start.
Mode Selection
•
Select the mode using
.
(When changing the mode without the front cover in place, turn the power off and restart the test mode.)
Starting and stopping operation
•
With the front cover in place
Press the
switch.
•
Without the front cover in place
Press SW1
Test Modes
Mode
Mode selection button
Z (zigzag)
operations
F (feed)
operations
Operating speed
3 point needle
drop
With front cover
in place
Press
twice,
select
.
Switches left base
line / center base
line / right base line
with each stitch
*Pressing
/
SW5 stops the base
line from changing
0 mm
(none)
Any speed may be
selected using the
speed control key
Without front
cover
in place
SW5
Switches low /
middle / high speed
with each push of
SW3.
Feed forward
and reverse
With front cover
in place
Press
five
times,
select .
100 stitches forward on the left
base line
100 stitches reverse on the right
baseline
Switches low /
middle / high speed
with each push of the
.
Without front
cover
in place
SW3
Switches low /
middle / high speed
with each push of
SW5.
Main PCB assy
Summary of Contents for Innov-is PC210
Page 1: ......
Page 3: ...2 1 2 Disassembly ...
Page 6: ...2 4 ...
Page 7: ...3 1 3 Assembly ...
Page 10: ...3 4 ...
Page 11: ...4 1 4 Adjustment ...
Page 13: ......
Page 14: ...NX200 13C03HF882S60 NX200 ...