10. STANDARD ADJUSTMENTS
38
KE-434C,435C
10-6. Adjusting the thread take-up amount
At the time of shipment from the factory, the thread take-up amount (stroke) of the thread take-up lever (1) is set to the
standard setting of 5 mm. You may need to adjust this setting depending on the sewing conditions to prevent the thread from
pulling out at the sewing start.
[Adjustment method]
Loosen the screw (2) and move the stopper (3.57 nut) (3) to adjust the operating angle of the thread take-up solenoid (4).
[KE-434C]
*
To reduce the thread take-up amount, move the stopper (3) upward.
*
To increase the thread take-up amount, move the stopper (3) downward.
[KE-435C]
*
To reduce the thread take-up amount, move the stopper (3) downward.
*
To increase the thread take-up amount, move the stopper (3) upward.
Note:
Do not increase the stroke of the thread take-up lever any more than is necessary.
If the sub-thread tension is too high, the needle thread length may become too short and the thread may come out of the
needle. Furthermore, if the sub-thread tension is too weak, the needle thread length may become too long and the
underside of the article being sewn may become untidy.
‘½‚-‚È‚é
Thread take-up amount (stroke)
2560Q
2614Q
2559Q
Become greater
Become less
[
KE-434C
]
[
KE-435C
]
Become greater
Become less