13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
55
KE-434C,435C
13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
The functions of the switches on the operation panel (1) can be changed to carry out special functions.
Note:
After changing the memory switch settings, press the power switch to turn the power off and then back on again.
1. Turn on the power switch.
2. While pressing the TEST switch (2), press the BOBBIN.
WIND switch (3).
* “00 - - ” will appear in the display window (4).
3. Press the DISPLAY SET switches (5) to set the two
digits at the left of the display window (4) to the
corresponding number (00 to 4F) of the function shown
in the table below that you would like to select.
4. When the BOBBIN. WIND switch (3) is pressed, the
two spaces at the right in the display window will
change from “ - - ” to “ON”.
* If you press the RESET switch (6) at this time,
memory switches will be returned to their initial
settings (factory default settings).
5. Press the TEST switch (2).
* The display will return to normal.
<Memory switches 00 - 0F>
Initial value
Switch
Motion when set to ON
Solenoid
Pneumatic
memo-00
At the end of sewing, the feed plate will be returned to the sewing start point via
mechanical home position.
--
--
memo-01
Work clamp will move to the sewing start point, and then will be lifted.
ON
ON
memo-02
Feed will move automatically to the next starting point at the same time as a user
program is switched.
(Normally it moves to the starting point after sewing starts.)
--
--
memo-03
When sewing using programs, the programs which have been set will be sewn in
numerical order. (Cycle sewing mode is set.)
--
--
memo-04
The sewing speed will be fixed at the minimum speed for the maximum pitch of
the sewing data. (Set this to ON if you are concerned that variations in pitch may
cause changes in the sewing speed.)
--
--
memo-05
Increases the presser solenoid lifting force (Set to ON when using the optional
spring for extra-heavy material)
* 1
--
memo-06
Enlargement and reduction ratio settings for X and Y become the same.
--
--
memo-07
The inner clamping device can be used with pneumatic specifications.
--
* 2
memo-08
Test feeding is carried out stitch by stitch when the foot switch is depressed.
--
--
memo-09
The sewing start point becomes the reference point for enlargements and
reductions. (The reference point for enlargements and reductions is
normally the center of the sewing frame.)
--
--
memo-0A
−
--
--
memo-0b
−
--
--
memo-0c
Needle stops in up position during emergency stop.
--
--
memo-0d
The bar tacking stitches (with a pitch of less than 1 mm) are also enlarged and
reduced. (Normally stitches with a pitch of less than 1 mm are not enlarged or
reduced.)
--
--
memo-0E
Test feeding will be performed at the same speed as that for actual sewing. (This
is used for checking feeding operation.)
--
--
memo-0F
After sewing is finished, the work clamp automatically opens and closes once
(practice operation).
--
--
*1
ON for solenoid/heavy material specifications, and “--” for solenoid/medium material specifications
-- : OFF
*2
ON when the inner clamping device is being used, and “--” at other times
2590Q