![background image](http://html.mh-extra.com/html/brother/lx-1200/lx-1200_service-manual_19957045.webp)
3-23
3.9 Roller Holder Assy
3.9.1
Removing the Roller Holder Assy
1. Lift up the Roller holder unit and disconnect the Roller holder return spring.
2. Remove the four Retaining rings (two from the Roller holder, two from the Paper
feed holder), then remove the Roller holder unit.
3. Remove the plastic spacer from the rivet pins at each end of the Roller holder assy.
Spacer
Retaining rings
Roller holder unit
Roller holder return spring
Retaining rings
Spacer
Fig. 3.9-1
Removing the Roller Holder Assy
Summary of Contents for LX-1200
Page 1: ...SERVICE MANUAL MODEL LX 1200 LX 300 ...
Page 2: ...COOL LAMINATOR SERVICE MANUAL MODEL LX 1200 LX 300 ...
Page 5: ...Chapter 1 SPECIFICATIONS ...
Page 9: ...Chapter 2 MECHANISMS ...
Page 20: ...Chapter 3 DISASSEMBLY PROCEDURES ...
Page 58: ...Chapter 4 ASSEMBLY PROCEDURES ...
Page 105: ...Chapter 5 ELECTRONIC CONTROLLERS ...
Page 127: ...Chapter 6 MAINTENANCE ...
Page 149: ...Chapter 7 TROUBLESHOOTING ...