2-93
Confidential
4.12 Troubleshooting for Image Defects
4.12.1 Defect examples
Fig. 2-15
4.12.2 Troubleshooting according to image defect
Light
<User Check>
- Check that the contrast setting is not too light.
- Clean the document glass or the ADF glass.
- Clean the first side document hold or second side document hold.
Step
Cause
Remedy
1
Incorrect white level correction data Execute function code 55.
2
First side CIS unit or second side
CIS unit failure
Replace the first side CIS unit or second
side CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.
Light
Dark or
bluish white
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...