3-54
Confidential
(6) Disconnect the touch panel harness and LCD flat cable from the panel PCB ASSY.
(7) Remove the screw pan (S/P washer) M3x6 DA screw to remove the touch panel PCB
harness.
(8) Remove the two screw pan (S/P washer) M3x6 DA screws from the panel PCB ASSY.
(9) Release the six hooks, and remove the panel PCB ASSY from the panel cover.
Fig. 3-68
(10) Remove the rubber keys L and R from the panel cover.
(11) Remove the panel light guide from the panel cover.
(12) Open the film to remove the seven taptite cup B M3x10 screws, and remove the touch
panel plate from the control panel ASSY.
Fig. 3-69
Assembling Note:
• When securing the touch panel plate with screws, tighten the screws in the
sequence of the numbers engraved on the touch panel plate.
Touch panel PCB harness
Hooks
Screw pan (S/P washer) M3x6 DA
Hooks
Panel cover
LCD flat cable
Panel PCB ASSY
Touch panel harness
Hooks
Screw pan (S/P washer) M3x6 DA
Rubber key L
Taptite cup B M3x10
Film
Touch panel plate
Taptite cup B M3x10
Panel cover
Panel light guide
Rubber key R
5
6
7
1
2
3
4
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...