Confidential
(2) Remove the two taptite bind B M4x12 screws, and release the hook to open the upper
side of the hold cover 2.
(3) Release the main fan harness from the securing fixtures, and remove the main fan from
the machine.
Fig. 3-112
Harness routing: Refer to
“5.Toner LED PCB ASSY/Main fan”
.
Assembling Note:
• Attach the main fan so that the surface with the label faces out.
Main fan
Label
Taptite bind B M4x12
Hold cover 2
Hook
Main fan
harness