1.3.7 Check LCD operation (function code: 12)
<Function>
This function is used to check that the LCD on the control panel is operating normally.
<Operation Procedure>
(1) Press the [1] and [2] buttons in this order in the initial state of maintenance mode. The LCD
appears as in <Display 1> in the table below.
(2) Each press of the [Start] button cycles through the screens as shown in the table below.
(3) When the [Stop/Exit] button is pressed, the machine returns to the initial state of
maintenance mode, regardless of the display status.
Fig. 5-4
Non touch panel model
Touch panel model
<Display 1>
Backlight : ON
LCD: Complete black
<Display 1>
Complete white
<Display 2>
Complete black
<Display 3>
Complete red
<Display 4>
Complete green
<Display 5>
Complete blue
<Display 6>
Complete gray
<Display 7>
Stroke detection
screen
<Display 2>
Backlight : ON
LCD: Complete white
<Display 3>
Backlight : OFF
LCD: Complete black
<Display 4>
Backlight : OFF
LCD: Complete white
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...