1.3.25 Check fan operation (function code: 78)
<Function>
This function is used to check that the main fan is operating normally. The rotation speed is
changed among three settings: 100%, 50% and OFF.
<Operation Procedure>
(1) Press the [7] and [8] buttons in this order in the initial state of maintenance mode. "F 100" is
displayed on the LCD, and the main fan operates at 100% rotation speed.
If the main fan is faulty, "NG" is displayed on the LCD.
(2) Press the [Start] button. "F 50" is displayed on the LCD, and the main fan operates at
50% rotation speed.
(3) Press the [Start] button. "F 0" is displayed on the LCD, and the main fan stops.
(4) Press the [Start] button. "F 100" is displayed on the LCD, and the status returns to step
(2). Each press of the [Start] button repeats from steps (2) to (4).
(5) When the [Stop/Exit] button is pressed, the machine returns to the initial state of
maintenance mode.
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...