Confidential
5-79
5.1.74 Paper Guide (C) PU / Paper Sensor (PT1, PEU) / OHP Sensor PU / Tray Empty Actuator
PU
(1) Disconnect the connector connecting to the paper sensor (PT1).
(2) Remove the setscrew (BT3x8, 2 pieces) of the paper guide (C) PU.
(3) Disconnect the connector connecting to each sensor of the paper guide (C) PU.
(4) Remove the paper guide (C) PU from the frame.
(5) Remove the paper sensor (PT1) from the paper guide (C) PU.
(6) Remove the setscrew (BT3x8, 2 pieces) fixing the OHP sensor PU.
(7) Remove the OHP sensor PU (Board) from the paper guide (C) PU.
(8) Remove the tray empty actuator PU from the paper guide (C) PU.
(9) Remove the harness from the paper sensor (PEU).
(10) Remove the paper sensor (PEU) from the paper guide (C) PU.
Fig. 5-123
BT3x8
Paper sensor (PT1)
Paper guide (C) PU
Frame
BT3x8
OHP sensor PU
Tray empty actuator PU
Paper sensor (PEU)
Harness
Connector
Connector
Connector
Summary of Contents for MFC-9420CN
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC 9420CN ...
Page 16: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 22: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 33: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 48: ...Confidential 3 1 4 CBV DBV Fig 3 16 Y M C K Fig 3 17 ...
Page 69: ...Confidential 3 3 5 Fig 3 35 ...
Page 73: ...Confidential 3 3 9 3 Interface Circuit Printer side Fig 3 38 ...
Page 82: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 85: ...Confidential 4 2 Cover page sample End page sample Fig 4 1 ...
Page 86: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 94: ...Confidential 5 5 5 1 1 AC Cord 1 Disconnect AC cord from the machine Fig 5 1 AC cord Machine ...
Page 175: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 203: ...Confidential CHAPTER 7 CLEANING ...
Page 205: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 213: ...8 6 Confidential Fig 8 2 Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 224: ...8 17 Confidential Cover page sample End page sample Fig 8 8 ...
Page 255: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 279: ...Confidential 9 23 2 Image failure 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Page 280: ...Confidential 9 24 15 a 15 b 16 17 18 19 20 21 22 23 24 25 Fig 9 1 ...
Page 325: ...App 1 5 Confidential 6 Transfer Unit X X X X X X 7 1 2 3 Location SERIAL NO YEAR MONTH DATE ...