4-38
Confidential
(6) In the
Serial No
box on the BrUsbSn screen, type the 15-digit serial number (e.g.,
U62663C0F000136) printed on the nameplate labeled to the machine as an ID code.
Tip:
The serial number can also be changed with Function code 80. (Refer to
Section 5.1.4.30 "Display of the Equipment's Log (Function code 80) (User-accessible)."
(7) In the
Head Info.
box, type the 13-digit property code (e.g., ALR7795500000) which is
printed on the bar code label attached to the lower cover. Click the
OK
key.
Tip:
The head property code can also be entered using Function code 68. (Refer to
(8) Check whether the entered character strings (ID code and head property code) are correct
with the following procedure.
In the initial stage of the maintenance mode, press the
8
and
0
keys in this order to call up
the log information on the LCD.
Press the
Black
Start
(
Mono Start
) key several times to display "S/N" on the LCD, then
press
OK
key. Check that the displayed code is that string entered in step (6).
Next, press the
Black
Start
(
Mono Start
) key once to display the head property code.
Check that the displayed code is the string entered in step (7).
(9) If both are OK, proceed to [ 10 ].
If something wrong is displayed, check the connection between the PC and machine and go
back to step (2).
Serial number label
(app01b_M11)
Head property label
(Bar code label)
(head_property_M11)
Summary of Contents for MFC-J6510DW
Page 15: ...xii Confidential ...
Page 16: ...xiii Confidential ...
Page 17: ...xiv Confidential ...
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 128: ...3 3 Confidential 3 2 PACKING For models with paper tray 2 ...
Page 273: ...4 13 Confidential EXIT Adjust Check Pattern 1 ...
Page 274: ...4 14 Confidential EXIT Adjust Check Pattern 2 ...
Page 275: ...4 15 Confidential EXIT Adjust Check Pattern 3 ...
Page 276: ...4 16 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 278: ...4 18 Confidential KEISEN GAP EXIT ADJUST PATTERN Line 1 Line 2 Line 3 ...
Page 280: ...4 20 Confidential Vertical Alignment Check Patterns ...
Page 283: ...4 23 Confidential Left Right and Bottom Margin Check Pattern ...
Page 286: ...4 26 Confidential Print Pattern for Creating Head Calibration Data ...
Page 302: ...4 42 Confidential ADF Copy Chart C A B D ...
Page 312: ...5 8 Confidential Print Pattern for Creating Head Calibration Data ...
Page 314: ...5 10 Confidential Scanning Compensation Data List ...
Page 317: ...5 13 Confidential Nozzle Test Pattern ...
Page 320: ...5 16 Confidential Configuration List ...
Page 337: ...5 33 Confidential EXIT Adjust Check Pattern 1 ...
Page 338: ...5 34 Confidential EXIT Adjust Check Pattern 2 ...
Page 339: ...5 35 Confidential EXIT Adjust Check Pattern 3 ...
Page 340: ...5 36 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 346: ...5 42 Confidential Vertical Alignment Check Pattern ...
Page 349: ...5 45 Confidential Left Right and Bottom Margin Check Pattern ...
Page 383: ...6 4 Confidential Power supply PCB 100 V series ...
Page 384: ...6 5 Confidential Power supply PCB 200 V series ...
Page 385: ...6 6 Confidential Wiring diagrams ...