2-40
Confidential
Error Code 5D
Driver IC overcurrent protection activated when the purge cam was being driven.
Error Code 5E
Driver IC overcurrent protection activated when the pump was in operation.
Step
Cause
Solution
8
Maintenance unit defective
Replace the maintenance unit.
9
Engine unit defective
Replace the engine unit.
10
Main PCB defective
Replace the main PCB ASSY.
11
Power supply PCB defective
Replace the power supply PCB.
Unable to Clean 5D
LCD
Unable to Clean 5E
LCD
Step
Cause
Solution
1
Main drain tube bent
Reconnect the main drain tube.
2
Foreign materials in the
maintenance unit or around the
paper feed roller
Remove foreign materials.
3
Ink supply tubes bent
Replace the ink refill ASSY.
4
ASF switching gear broken
Replace the ASF switching gear.
5
Maintenance unit defective
Replace the maintenance unit.
6
Engine unit defective
Replace the engine unit.
7
Main PCB defective
Replace the main PCB ASSY.
Summary of Contents for MFC-J6510DW
Page 15: ...xii Confidential ...
Page 16: ...xiii Confidential ...
Page 17: ...xiv Confidential ...
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 128: ...3 3 Confidential 3 2 PACKING For models with paper tray 2 ...
Page 273: ...4 13 Confidential EXIT Adjust Check Pattern 1 ...
Page 274: ...4 14 Confidential EXIT Adjust Check Pattern 2 ...
Page 275: ...4 15 Confidential EXIT Adjust Check Pattern 3 ...
Page 276: ...4 16 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 278: ...4 18 Confidential KEISEN GAP EXIT ADJUST PATTERN Line 1 Line 2 Line 3 ...
Page 280: ...4 20 Confidential Vertical Alignment Check Patterns ...
Page 283: ...4 23 Confidential Left Right and Bottom Margin Check Pattern ...
Page 286: ...4 26 Confidential Print Pattern for Creating Head Calibration Data ...
Page 302: ...4 42 Confidential ADF Copy Chart C A B D ...
Page 312: ...5 8 Confidential Print Pattern for Creating Head Calibration Data ...
Page 314: ...5 10 Confidential Scanning Compensation Data List ...
Page 317: ...5 13 Confidential Nozzle Test Pattern ...
Page 320: ...5 16 Confidential Configuration List ...
Page 337: ...5 33 Confidential EXIT Adjust Check Pattern 1 ...
Page 338: ...5 34 Confidential EXIT Adjust Check Pattern 2 ...
Page 339: ...5 35 Confidential EXIT Adjust Check Pattern 3 ...
Page 340: ...5 36 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 346: ...5 42 Confidential Vertical Alignment Check Pattern ...
Page 349: ...5 45 Confidential Left Right and Bottom Margin Check Pattern ...
Page 383: ...6 4 Confidential Power supply PCB 100 V series ...
Page 384: ...6 5 Confidential Power supply PCB 200 V series ...
Page 385: ...6 6 Confidential Wiring diagrams ...