5-37
Confidential
5.1.4.17 Checking of CIS Travel
(Function code 59)
Function
This procedure allows you to check the movement of the CIS unit integrated in the scanner
cover (scanner unit). The CIS unit travels to the three positions--the white reference film
position, scanning start and end positions.
Operating Procedure
-- Check the movement of the CIS unit --
(1) Press the
5
and
9
keys in this order in the initial stage of the maintenance mode.
Simplex scanning models
The "1:MONO 2:COLOR?" appears on the LCD.
Duplex scanning models
The "CIS 1:FB 2:ADF" appears on the LCD.
Press the
1
key to display "1: MONO 2:COLOR?"
(2) To call up the CIS travel menu, press the
1
key.
(The "2:COLOR" is for checking scanning clocks at the factory, so do not access it.)
The "RESO TYPE SET 1" appears on the LCD.
(3) Press the
OK
key (
PHOTO CAPTURE
key for models without
OK
key).
The "LED PWM : **" appears on the LCD.
(4) Press the
OK
key (
PHOTO CAPTURE
key for models without
OK
key).
The "G PULSE : ****" appears on the LCD.
(5) Press the
OK
key (
PHOTO CAPTURE
key for models without
OK
key).
The "1:WHT 2:FRT 3:MV" appears.
(6) Press the
3,
1,
or
2
key, then press the
OK
key (
PHOTO CAPTURE
key for models
without
OK
key).
The CIS unit moves to the scanning end position, white reference film position, or scanning
start position, respectively.
(7) Press the
Stop/Exit
key, and the CIS unit returns to the home position.
The machine returns to the initial stage of the maintenance mode.
Summary of Contents for MFC-J6510DW
Page 15: ...xii Confidential ...
Page 16: ...xiii Confidential ...
Page 17: ...xiv Confidential ...
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 128: ...3 3 Confidential 3 2 PACKING For models with paper tray 2 ...
Page 273: ...4 13 Confidential EXIT Adjust Check Pattern 1 ...
Page 274: ...4 14 Confidential EXIT Adjust Check Pattern 2 ...
Page 275: ...4 15 Confidential EXIT Adjust Check Pattern 3 ...
Page 276: ...4 16 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 278: ...4 18 Confidential KEISEN GAP EXIT ADJUST PATTERN Line 1 Line 2 Line 3 ...
Page 280: ...4 20 Confidential Vertical Alignment Check Patterns ...
Page 283: ...4 23 Confidential Left Right and Bottom Margin Check Pattern ...
Page 286: ...4 26 Confidential Print Pattern for Creating Head Calibration Data ...
Page 302: ...4 42 Confidential ADF Copy Chart C A B D ...
Page 312: ...5 8 Confidential Print Pattern for Creating Head Calibration Data ...
Page 314: ...5 10 Confidential Scanning Compensation Data List ...
Page 317: ...5 13 Confidential Nozzle Test Pattern ...
Page 320: ...5 16 Confidential Configuration List ...
Page 337: ...5 33 Confidential EXIT Adjust Check Pattern 1 ...
Page 338: ...5 34 Confidential EXIT Adjust Check Pattern 2 ...
Page 339: ...5 35 Confidential EXIT Adjust Check Pattern 3 ...
Page 340: ...5 36 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 346: ...5 42 Confidential Vertical Alignment Check Pattern ...
Page 349: ...5 45 Confidential Left Right and Bottom Margin Check Pattern ...
Page 383: ...6 4 Confidential Power supply PCB 100 V series ...
Page 384: ...6 5 Confidential Power supply PCB 200 V series ...
Page 385: ...6 6 Confidential Wiring diagrams ...