E-18
PD-9810
Chapter 4 PARAMETER
Parameter Table
Described below is the contents of the parameter that is set on each program.
•
The parameter values can be stored independently for each program. Each parameter for the taper
tack and the straight bar tack is also independently stored.
•
The allowable setting range for some parameters may vary from the range specified, depending on
the settings of each other parameters.
•
Two kinds of specifications for the taper tack and the straight bar tack are available as to the
machine and a part of parameters vary with the specifications of the connected machines.
When the programmer is connected to the machine with the taper tack
specifications
No.
Setting items
Setting range
Unit
Default
00
Sewing speed
1,000
∼
2,200rpm
100
1,800
01
Eyelet pattern
1
∼
6
1
2
02
Button hole length (Note 1)
-00:5
∼
50mm
-01:5
∼
38mm
-02(L1):14
∼
18mm
(L2):18
∼
22mm
(L3):22
∼
26mm
(L4):26
∼
30mm
(L5):28
∼
32mm
(L6):32
∼
36mm
(L7):36
∼
40mm
1
-00:25mm
-01:25mm
-02(L1):16mm
(L2):20mm
(L3):24mm
(L4):28mm
(L5):30mm
(L6):34mm
(L7):38mm
03
Taper length
0
∼
20mm
1
6
04
Offset
0.5
∼
2.0mm
0.1
1.5
05
Stitch pitch
0.5
∼
2.0mm
0.1
1.0
(Note 1)
Setting ranges and defaults of stitch lengths may vary with the machine sub-class.
Summary of Contents for PD-9810
Page 1: ...PD 9810 PROGRAMMER ENGLISH ...
Page 2: ......
Page 7: ...Chapter 1 INTRODUCTION ...
Page 14: ...E 8 PD 9810 Chapter 1 INTRODUCTION ...
Page 15: ...Chapter 2 PREPARATION ...
Page 19: ...Chapter 3 EXAMPLE OF THE PROGRAM CHANGE PROCEDURE ...
Page 23: ...Chapter 4 PARAMETER ...
Page 32: ...E 26 PD 9810 Chapter 4 PARAMETER ...
Page 33: ...Chapter 5 PROGRAM READING AND WRITING ...
Page 39: ...Chapter 6 HANDY FUNCTIONS ...
Page 42: ...Chapter 6 HANDY FUNCTIONS E 36 PD 9810 ...
Page 43: ...Chapter 7 OTHER FUNCTIONS ...
Page 62: ...E 56 PD 9810 Chapter 7 OTHER FUNCTIONS ...
Page 63: ...Chapter 8 ERROR MESSAGE ...