2-12
Confidential
Error code 2014
ADF cover sensor detected an open ADF cover.
Error code 2024
When the power switch is turned ON, write a certain value to NVRAM then read again, the
value is different.
Error code 2036
When the power switch is turned ON, an error occurred in the read value of the multi-feed
sensor.
Error code 2037
When the power switch is turned ON, write a certain value to first side AFE register then read
again, the value is different.
ADF cover open.
<User Check>
• Close the ADF cover properly.
Step
Cause
Remedy
1
Sensor PCB attachment failure Reattach the sensor PCB ASSY.
2
Abrasion of the ADF cover hook Replace the ADF cover hook.
3
ADF cover sensor failure
Replace the sensor PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
NVRAM R/W test error.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Ultrasonic error.
<User Check>
• Remove the document in the product, if any.
Step
Cause
Remedy
1
Deviated adjustment value of
the multi-feed sensor
Readjust the multi-feed sensor. (Refer to
Setting Multi-feed Sensor Threshold” in
Chapter 4
2
Multi-feed sensor PCB
(Receive) failure
Replace the multi-feed sensor PCB ASSY
(Receive).
3
Multi-feed sensor PCB
(Transmit) failure
Replace the multi-feed sensor PCB ASSY
(Transmit).
4
Main PCB failure
Replace the main PCB ASSY.
AFE R/W test error.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for PDS-5000
Page 23: ...2 4 Confidential 2 2 Document Feed Path Fig 2 2 Front side Document feed path Back side ...
Page 45: ...3 2 Confidential 2 PACKING Fig 3 1 ...
Page 48: ...3 5 Confidential 5 LUBRICATION There are no parts that require lubrication ...
Page 49: ...3 6 Confidential 6 OVERVIEW OF GEARS Left side Fig 3 3 Right side Fig 3 4 ...
Page 138: ...5 1 Confidential CHAPTER 5 SERVICE FUNCTIONS Service mode is not equipped with this product ...