2-19
Confidential
Faulty registration
Dark
Completely blank
<User Check>
- Check that the document scanning position setting is
not deviated.
Step
Cause
Remedy
1
OD adjustment value failure
Acquire OD adjustment value. (Refer to
OD Adjustment (Optical Density Learning)”
in Chapter 4
.)
2
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check that the contrast setting is not too dark.
Step
Cause
Remedy
1
OD adjustment value failure
Acquire OD adjustment value. (Refer to
OD Adjustment (Optical Density Learning)”
in Chapter 4
2
Attachment failure of the spring in
second side glass ASSY
Reattach the spring in the second side glass
ASSY.
3
First side LED light PCB or second
side LED light PCB failure
Replace the first side LED light PCB or
second side LED light PCB.
4
First side CCD unit or second side
CCD unit failure
Replace the first side CCD unit or second
side CCD unit.
5
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check that the document is not reversed.
Step
Cause
Remedy
1
Connection failure of the first side
or second side CCD flat cable
Reconnect the first side or second side CCD
flat cable.
2
First side LED light PCB or second
side LED light PCB failure
Replace the first side LED light PCB or
second side LED light PCB.
3
First side CCD unit or second side
CCD unit failure
Replace the first side CCD unit or second
side CCD unit.
4
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for PDS-5000
Page 23: ...2 4 Confidential 2 2 Document Feed Path Fig 2 2 Front side Document feed path Back side ...
Page 45: ...3 2 Confidential 2 PACKING Fig 3 1 ...
Page 48: ...3 5 Confidential 5 LUBRICATION There are no parts that require lubrication ...
Page 49: ...3 6 Confidential 6 OVERVIEW OF GEARS Left side Fig 3 3 Right side Fig 3 4 ...
Page 138: ...5 1 Confidential CHAPTER 5 SERVICE FUNCTIONS Service mode is not equipped with this product ...