3-29
Confidential
(3) Unlock the lock to disconnect the LCD PCB flat cable from the LCD PCB ASSY.
(4) Remove the two taptite cup B M3x8 screws to remove the LCD PCB ASSY from the
panel ASSY.
Fig. 3-33
Harness routing: Refer to
and
.
Note:
• After disconnecting flat cable, check that the cable is not damaged at its end or
short-circuited.
• When connecting flat cable, do not insert it at an angle. After insertion, check that
the cable is not at an angle.
LCD PCB flat cable
Taptite cup B M3x8
Panel ASSY
LCD PCB ASSY