- 28 -
15.
NEEDLE THREADER (REPLACING THE HOOK)
•
If the point of the hook becomes bent or broken, the hook must be replaced.
STANDARD HOOK DIMENSIONS
REPLACING THE HOOK
1.
Remove the two hook mounting screws.
2.
Replace the hook with a new one, and then tighten the two hook mounting screws.
Caution
•
Do not over-tighten the hook mounting screws, as this could strip the screw threads, which will make
tightening impossible.
3.
If the hook doesn’t pass correctly through the needle hole after the hook has been replaced, adjust the
needle threader position. (Refer to "ADJUSTMENT" in "14. NEEDLE THREADER (ADJUSTING THE
NEEDLE THREADER).")