-66-
PROBLEM
CAUSE
CORRECTION
16.The stitch
shown in the
pattern
indication
window is
different from
the one being
sewn.
1. Release volume is too small.
2. The indicate gear and pattern indicator plate are not
aligned correctly.
1. Adjust the release volume.
* Refer to P.37.
2. Adjust the pattern indicator.
* Refer to P.47.
17.Light is off.
1. Inferior light bulb.
1. Replace the light bulb.
18.Motor does not
run.
1. Inferior foot controller.
2. Inferior motor or inferior brush.
1. Replace the foot controller.
2. Replace the motor.
* Be sure to turn off the power.
www.promelectroavtomat.ru
Summary of Contents for PS-53
Page 1: ... 7 2001 www promelectroavtomat ru ...
Page 4: ... 2 1 MECHANICAL CHART www promelectroavtomat ru ...
Page 8: ... 6 3 ELECTRONIC PARTS ARRANGEMENT CHART STAR240E STAR230E only www promelectroavtomat ru ...
Page 31: ... 29 2 LEAD WIRES ARRANGEMENT STAR240E STAR230E PS57 PS55 PS53 www promelectroavtomat ru ...
Page 77: ...STAR240E STAR230E PS 57 PS 55 PS 53 H1060212 www promelectroavtomat ru ...