III-17
[ 13 ]
Disassembling the Mechanical Unit
(1)
Remove two screws securing the tape feed motor from the bottom side and remove the tape
feed motor ASSY.
Fig. 3.1-26 Removing the Tape Feed Motor ASSY
(2)
Remove a screw to remove the AV SW sensor ASSY from the main frame.
Fig. 3.1-27 Removing the AV Sensor Actuator/AV SW Sensor ASSY (1)
Tape feed motor ASSY
Main frame
Screws
Screw
AV SW sensor ASSY
Main frame