5. POWER SUPPLY EQUIPMENT
RH-981A
102
5-6-1. Memory switch table
The memory switch settings are applied immediately to all programs once the settings have been changed.
However, memory switches marked with * are only applied after the power is turned on.
No.
Setting items
Setting range
Unit
Default
00.
Work clamp down operation when feed bracket is
forward
OFF, ON
-
OFF
01.
Work clamp stays down after sewing
OFF, ON
-
OFF
02.
Number of home position start cycles (Note 1)
OFF, 1 - 9
1
1
03.
Cutting block ON time
25 - 200 ms
25 ms
25 ms
04.
Timer for checking raising of hammer
(Timer for determining if the cutting block has been
raised to a position where it will not touch the next
feed bracket to operate)
OFF (Determined
from number of slit
signals),
200 - 500 ms
50 ms
OFF
05.
Feed operation timing correction after hammer is
raised
(After checking that the hammer is raised, the timer
interval is added so that the hammer and feed
bracket do not touch.)
0 - 150 ms
25 ms
0
06.
Test feeding deceleration speed
OFF, 1 - 4
1
OFF
07.
Increased amount of upper thread remaining
OFF, 1 - 3
1
OFF
08.
Stitch length display in automatic mode
OFF, ON
-
OFF
09.*
Max. stitch length of L7
40 mm, 42 mm
2 mm
40 mm
10.
Feed timing correction
-10 - 10
1
0
11.*
Number of eyelet buttonholes when fly indexer is
used
OFF (Fly indexer is
not used),1 - 9
1
1
12.*
Cloth setting position when fly indexer is used
1: Left setting
position
2: Horizontal setting
position
1
1
13.
Program number selected when buttonhole sensor
is ON when using the special lapel cutting device
OFF, 1 - 9
1
OFF
14.
Program number for operating the straight
buttonhole hammer regardless of eyelet shape
setting (parameter No. 01) and whether the
buttonhole sensor is ON or OFF (Note 2)
OFF, 1 - 9
1
OFF
(Note 1) If home position starting is not carried out for each piece of material, there is the danger that the feed
bracket may become overloaded for some reason and come off, which will affect the next piece to be sewn.
Accordingly it is recommended that you set home position starting to be carried out each time (setting "1").
(Note 2) If a program number has been set for memory switch No. 13, it will be ignored if a program number has
been set for memory switch No. 14.