7. SOFTWARE
RH-981A
119
Code
Explanation
Resetting method
[ I ] Input check No.
[O] Output check code
E-45
Lower thread trimming OFF sensor is
OFF.
Turn off the power.
[ I ] 21
[O] C-04
E-50
X home position sensor is OFF when
it should be ON.
Turn off the power.
[ I ] 14
E-51
Y home position sensor is OFF when
it should be ON.
Turn off the power.
[ I ] 15
E-52
θ
home position sensor is OFF when it
should be ON.
Turn off the power.
[ I ] 16
E-59
Sewing data error
Turn off the power.
-
3. Errors during operation
Code
Explanation
Resetting method
[ I ] Input check No.
[O] Output check code
E-60
EMERGENCY STOP switch was
pressed.
Release the EMERGENCY STOP
switch, and then press the RESET
key.
-
E-62
Machine head is tilted back. (Head
sensor is OFF.)
Turn off the power.
[ I ] 19
E-66
Feed plate home position sensor is
not activated within a specified time.
Turn off the power.
[ I ] 22
E-67
Feed plate left range sensor is not
activated within a specified time.
Turn off the power.
[ I ] 23
[O] C-18
E-68
Feed plate right range sensor is not
activated within a specified time.
Turn off the power.
[ I ] 24
[O] C-18
E-70
Needle up sensor is not activated
within a specified time.
Turn off the power.
[ I ] 11
[O] C-07
E-71
Needle down sensor is not activated
within a specified time.
Turn off the power.
[ I ] 12
[O] C-07
E-72
Cutter sensor is not activated within a
specified time.
Turn off the power.
[ I ] 20
[O] C-06
E-75
Lower thread trimming OFF sensor is
not activated within a specified time.
Turn off the power.
[ I ] 21
[O] C-04
E-76
Needle up sensor is OFF during test
feeding.
Turn off the power.
[ I ] 11
E-77
Synch signal is not activated within a
specified time.
Turn off the power.
[ I ] 13
E-80
X home position sensor is not set to
ON within a specified time of
searching home position.
Turn off the power.
[ I ] 14
E-81
Y home position sensor is not set to
ON within a specified time of
searching home position.
Turn off the power.
[ I ] 15
E-82
θ
home position sensor is not set to
ON within a specified time of
searching home position.
Turn off the power.
[ I ] 16
E-89
Machine motor reverse operation error Turn off the power.
[O] C-07