2. DISASSEMBLY
RH-981A
10
2. DISASSEMBLY
CAUTION
Disassembly should only be carried out by a
qualified technician.
Turn off the power switch before disassembly,
otherwise the machine may operate if the start
switch is pressed by mistake, which could
result in injury.
Be sure to wear protective goggles and gloves
when handling the lubricating oil and grease,
so that they do not get into your eyes or onto
your skin, otherwise inflammation can result.
Furthermore, do not drink the oil or eat the
grease under any circumstances, as they can
cause vomiting and diarrhea.
Keep the oil out of the reach of children.
Disconnect the air hoses from the air supply and
wait for the needle on the pressure gauge to drop
to “0” before disassembly of any parts which use
the pneumatic equipment.
Use only the proper replacement parts as
specified by Brother.
If any safety devices have been removed, be
absolutely sure to re-install them to their original
positions and check that they operate correctly
before using the machine.
Any problems in machine operation which result
from unauthorized modifications to the machine
will not be covered by the warranty.
If disassembly is not performed in the correct order, it may be hard to remove parts. Disassemble as follows.
The following is the main points of disassembly.
2-1. Covers and work clamp mechanism
1. Remove the needle (1).
2. Remove the face plate (2), the belt cover F (3), the belt cover R (4), the top cover (5), the zigzag window cover (6),
and the driving needle guard cover (7).
3. Remove the work clamp plates R (8) and L (9).