3. ASSEMBLY
RH-981A
47
3-15. Covers and work clamp mechanism
1. Attach the work clamp plates R (1) and L (2).
2. Attach the driving needle guard cover (3), the zigzag window cover (4), the top cover (5), the belt cover F (6), the
belt cover R (7), and the face plate (8).
3. Attach the needle (9).
3-16. Safety switch
1. Switch to the input check mode.
2. Adjust the height of the safety switch (1) using the two screws (2) so that the LED does not go off even if the
machine head is lowered and the bed is shaken up and down.
3771Q
3770Q
3769Q
3772Q
3773Q
LED is lit.