S-7300A
3. FUNCTION SETTINGS
20
No. Setting range
Initial
value
Setting
units
Setting details
956
300
~
5000
(sti/min)
3000
(sti/min)
100
Speed selected mid speed SW (option input 2)
(*) Displayed when MSW-950 is set to "3".
960
OFF,1
~
4
OFF
1
Function of option output 3
OFF: No output
1: Puller
2: Operation sync output (needle cooler)
3: Pneumatic wiper
4: Variable output
961
0
~
99
(needle)
0
1
Needle counting from beginning sewing until puller output is OFF
(*) Displayed when MSW-960 is set to "1".
0: No stitch number control
1 to 99: Stitch number control enabled
962
5
~
30
(seconds)
10
(seconds)
1
Puller output ON timing when sewing motor stops.
(*) Displayed when MSW-960 is set to "1".
963
0
~
990
(ms)
10
(ms)
10
Delayed timing from presser foot solenoid is ON to pneumatic wiper output
ON
(*) Displayed when MSW-960 is set to "3".
964
0.1
~
2.0
(seconds)
2.0
(seconds)
0.1
Pneumatic wiper output ON time
(*) Displayed when MSW-960 is set to "3".
965
0
~
99
(needle)
0
(needle)
1
Needle counting from option input 2 is ON until option output is ON
(*) Displayed when MSW-960 is set to "4".
966
0
~
99
(needle)
0
(needle)
1
Needle counting from option input2 is OFF until option output3 is OFF
(*) Displayed when MSW-960 is set to "4".