55
6
Cleaning
1
Switch the machine off and unplug it.
2
Raise the needle and the presser foot.
3
Loosen the presser-foot screw and the needle
clamp screw to remove the presser-foot
holder and the needle.
4
Grasp both sides of the needle plate cover,
and then slide it toward you to remove the
needle plate cover.
1
Needle plate cover
5
Turn the balance wheel toward you until the
tip of the shuttle hook aligns with the edge of
the shuttle race shelf.
1
Shuttle-race shelf
2
Shuttle
3
Edge of the shuttle race
4
Tip of the shuttle hook
6
Remove the shuttle.
Grasp the shuttle, and then pull it out.
1
Shuttle
7
Use the cleaning brush or a vacuum cleaner to
remove any dust from the shuttle race and its
surrounding area.
1
Cleaning brush
2
Shuttle race
• Do not put oil on the shuttle.
●
Make sure you unplug the machine
before you clean it. Otherwise, you may
get an electric shock or be injured.
CAUTION
1
1
2
3
4
●
Make sure you turn the balance wheel
toward the front of the machine
(counterclockwise). Turning the balance
wheel in the other direction may damage
the machine.
CAUTION
1
1
2