1. Check the documentation to know which communication protocol is
used for the control of your appliance:
Tab.12 Communication protocol
A
On/off protocol
B
OpenTherm protocol
C
BSB protocol
2. Use the diagram to determine which gateway matches the
communication protocol of your appliance: Gateway 16 or 17
Important
If your appliance supports the R-bus communication protocol, you
don’t need a gateway.
6.4
Installation of the gateway
Warning
The installation must be performed by a qualified professional.
1. Switch off the appliance.
Important
Refer to the documentation of the appliance.
2. Install the gateway following the instructions in the gateway
documentation.
6.5
Location of the IDA
Choose the right location for the IDA.
1. Choose the room where you spend most of your time.
2. Choose a suitable place on the wall:
2.1. Away from heat sources (fire place, radiator, light, candles,
direct sunlight, etc.)
2.2. Away from draughts
3. Check that the distance between the IDA and the appliance or
gateway does not exceed 50 m (maximum cable length).
Fig.67
AD-3001015-01
A
OO
B
OT
C
BSB
Fig.68
AD-3001133-01
R-bus
16
OO
R-bus
16
OT
R-bus
17
BSB
Fig.69
AD-3001017-01
6 Installation
40
7726708 - v.01 - 18012019