BW1254 User Guide v1.0
Nov. 2013
Page 125 of 184
Input Bytes
– amount of data in bytes which the user network device has received [Bytes]
Output Bytes
– amount of data in bytes, transmitted by the user network device [Bytes]
Remaining Input/Output Bytes
– user session remaining input/output bytes. WISPr Operator can
define the user session in bytes. Remaining bytes is received from RADIUS [Bytes/unlimited]
Remaining Total Bytes
–user session remaining total bytes. WISPr Operator can define the user
session in bytes. Remaining bytes is received from RADIUS [Bytes/unlimited]
Bandwidth Downstream/Upstream
– user upstream and downstream bandwidth [in bps]
Back
– returns to connect client’s statistics list
Kickoff
– click this button to logout the user from access point.
Refresh
– click the button to refresh users’ statistics
User | Station Supervision
The
Station Supervision
function is used to monitor the connected host station availability. This
monitoring is performed with ping. If the specified number of ping failures is reached (
failure count
),
the user is logged out from the BW1254.
Figure 208 – Station Supervision
To adjust the ping interval/failure count, click the
Edit
button.
Figure 209 – Edit Station Supervision
Interval
– define interval of sending ping to host [in seconds]
Failure Count
– failure count value after which the user is logged out from the system
Save
– save station supervision settings
Cancel
– cancel changes
Change status or leave in the default state if no editing is necessary and click the
Save
button.