18
3.
The moisture indicator ring is placed into the
window first. Minimal handling is best, and care
should be taken with the packaging contents
and their disposal.
4.
This view shows the ring properly installed
in the window.
Inspect o-ring for wear, and
replace if worn.
Lube threads with food grade
silicone grease if needed.
1.
Unscrew window cap in counter-clockwise
direction. (NOTE: The orientation of the sight-
glass assembly may vary.)
2.
Here the cap is shown having been re-
moved, and the retaining spring exposed.
Old elements are removed from the window
at this time.
WARNING:
Make sure all pressure is relieved prior to changing element.
SIGHTGLASS CO MOISTURE ELEMENT CHANGE DEMONSTRATION
Replacement Element Part #
M7414 (Assy #
VM211-EL
)