13
(Figure 16). With the lever to the rear, shells are locked in the
magazine. Additionally, shells cannot be loaded into the magazine
with the lever to the rear.
2 Pull the bolt handle fully rearward to eject the shell in the chamber.
3 Load a shell through the ejection port.
the shotgun is now ready to Fire by siMPly Moving the ˝saFety”
to the oFF saFe Position and Pulling the trigger.
4 The shotgun may now be fired and will fire only the shell in the
chamber.
5 To disengage the Magazine Cut-Off, place the ˝safety” in the on
safe position, then push the Magazine Cut-Off lever fully forward
(Figure 17). If the action is open, shells will immediately feed from
the magazine. If the action is closed, a shell can be loaded into the
chamber from the magazine.
i n t e r c h A n G e A b l e c h o k e t u b e s Y s t e m
never atteMPt to reMove or install a choKe tube in a loaded
FirearM. whenever reMoving or installing a choKe tube in a
shotgun, always KeeP the MuZZle Pointed in a saFe direction.
coMPletely unload the shotgun. oPen the action and visually
insPect the chaMber, Feed MechanisM and MagaZine to be
absolutely certain the FirearM is coMPletely unloaded.
always Place the ˝saFety” in the on saFe Position and KeeP
your Fingers away FroM the trigger. Failure to Follow these warnings could result in serious
injury or death.
do not Fire this shotgun without the correct choKe tube installed. PerManent daMage May
result to the threads inside the barrel.
use only the aPProPriate gauge and tyPe oF choKe tubes, MarKed invector-Plus or standard
invector, dePending on your shotgun.
invector-Plus choKe tubes are For use only in browning shotguns with bacK-bored barrels,
and are not interchangeable with standard invector choKe tubes. do not use invector-Plus
tubes in barrels threaded For standard invector tubes.
standard invector tubes are For use only in browning shotguns, and are not interchangeable
with invector-Plus choKe tubes. do not use standard invector tubes in barrels threaded For
invector-Plus tubes.
do not use browning standard invector or invector-Plus choKe tubes in any shotgun barrels
not suPPlied by browning. do not use any other choKing device in any shotgun barrels
suPPlied by browning.
Failure to Follow these warnings May cause injury or death and cause daMage to your
shotgun.
All Maxus shotgun barrels are threaded to accept the Invector-Plus
™
choke system. Standard Invector
™
and
Invector-Plus tubes are not interchangeable. Confirm the choke system of your shotgun by looking on the
right side of the barrel where the specifications are inscribed, where the choke markings are normally
located.
The constriction of each choke tube is indicated twice on the choke tube: on the side of the tube, and
indicated with a ˝notch” code on the top rim of the tube. The included universal choke tube wrench is
Figure 16
pull the magazine cut-off rearward to block
the magazine.
Figure 17
push the magazine cut-off forward to unblock
the magazine.
E
N
BRO5180_Maxus A5_v7.indd 13
02/03/10 13:30
Summary of Contents for MAXUS
Page 6: ...4 E N BRO5180_Maxus A5_v7 indd 4 02 03 10 13 30 ...
Page 26: ...24 E N BRO5180_Maxus A5_v7 indd 24 02 03 10 13 30 ...
Page 27: ...25 Browning maxus Fusils semi automatiques F R BRO5180_Maxus A5_v7 indd 25 02 03 10 13 30 ...
Page 52: ...50 F R BRO5180_Maxus A5_v7 indd 50 02 03 10 13 30 ...
Page 53: ...51 Browning maxus HALBAUTOMATISCHE FLINTE D E BRO5180_Maxus A5_v7 indd 51 02 03 10 13 30 ...
Page 78: ...76 D E BRO5180_Maxus A5_v7 indd 76 02 03 10 13 31 ...
Page 79: ...77 Browning Maxus fucilE semiautomaticO I T BRO5180_Maxus A5_v7 indd 77 02 03 10 13 31 ...
Page 104: ...102 I T BRO5180_Maxus A5_v7 indd 102 02 03 10 13 31 ...
Page 105: ...103 Browning Maxus Escopeta SEMIautomática E S BRO5180_Maxus A5_v7 indd 103 02 03 10 13 31 ...
Page 130: ...128 NOTES E S BRO5180_Maxus A5_v7 indd 128 02 03 10 13 31 ...